///2010 Abstract Details
2010 Abstract Details2018-05-01T17:52:49+00:00

Combined spinal and epidural analgesia (CSEA) for labor : effects on uteroplacental blood flow and maternal catecholamines

Abstract Number: 123
Abstract Type: Original Research

Sergio E Cerda Associate Professor1 ; Sergio E E Cerda S Associate Professor2; Mauro Parra C Associate Professor3; Victor M Varela M Medicine Internship Rotation4; Diego Bustamante Assistant Professor5; Mario Herrera Associate Professor6

Introduction: CSEA has been associated with an earlier and higher incidence of fetal heart rate (FHR) changes. A fall in plasma epinephrine has been observed but other mechanisms and potencial effects on fetal well-being are not defined. Purpose of this study was to assess the effect of CSEA on umbilical and uterine blood flow and maternal catecholamines

Methods : After IRB approval and informed consent, healthy parturient women with singleton, uncomplicated pregnancies at term received CSEA with bupivacaine and fentanyl. Pain (VAS), maternal blood pressure, fetal and maternal heart rate, blood flow velocity waveforms and pulsatility indices (PI) of the uterine and fetal umbilical arteries were measured before and at 5, 10, 15 and 30 minutes following CSEA. Intervention criteria included IV TNT for uterine relaxation, IV ephedrine and volume loading to correct hypotension. Any other intervention excluded patient from study. FHR tracings were reviewed post hoc. Blood samples to measure plasma epinephrine, normetanephrine and serotonin by HPLC were drawn at baseline 10 and 30 minutes. Statystical analyses included repeated measures of analysis of variance (Friedman) and Bonferroni and Tukey post tests with p < 0.05 defined as significant.

Results: 60 patients were studied. VAS pain scores decreased significantly from 5 minutes. Systolic, diastolic and mean arterial blood pressures decreased significantly at 10 minutes and maternal heart rate from 10 to 30 minutes following CSEA. FHR did not change significantly and tracings did not showed altered patterns. After CSEA the uterine artery mean PI increased at 10 minutes (p<0.05) while no changes occurred in umbilical artery mean PI when compared to baseline. Apgar scores were within normal range in all newborns. Adrenalin and serotonin plasma levels decrease from 10 min onwards , and adrenalin / normetanephrine ratio decrease significantly after CSEA

Discussion : Maternal hemodynamics and FHR recording after CSEA may not reveal stable uteroplacental perfussion. The increase in uterine artery PI indicates increase in uterine vascular resistance without derrangement in fetal perfussion , as umbilical artery PI remained stable. Decrease in epinephrine after pain relief and imbalance in maternal catecholamines favoring noradrenaline vasoconstriction may explain these observations. Additional studies may contribute to define their clinical impact and cautious use of CSEA is suggested when compromised uteroplacental perfussion and fetal well being state are suspected.